Energy Hub Inverter w/ Prism Datasheet

Single Phase Energy Hub Inverter
with Prism Technology
For North America
SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US
(1)
SE3000H-US
SE3800H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US
UNITS
OUTPUT
-
AC ON GRID
Rated AC Power
3000
3800 @ 240V
3300 @ 208V
6000 @ 240V
5000 @ 208V
7600 10000
11400 @ 240V
10000 @ 208V
W
Maximum AC Power Output 3000
3800 @ 240V
3300 @ 208V
6000 @ 240V
5000 @ 208V
7600 10000
11400 @ 240V
10000 @ 208V
W
AC Frequency Range (min - nom - max)
Hz
Maximum Continuous Output Current @ 240V
12.5
16
25
32
42
47.5
A
Maximum Continuous Output Current @ 208V
-
16
24
-
-
48.5
A
GFDI Threshold
A
Total Harmonic Distortion (THD)
%
Power Factor
Utility Monitoring,IslandingProtection,Country ConfigurableThresholds
Charge Battery from AC (if allowed)
Typical Nighttime Power Consumption
W
OUTPUT
-
AC BACKUP
(
3
)
Rated AC Power in Backup Operation
(4)
3000
3800
6000
7600
10000 10300 W
7600*
10300*
AC L-L Output Voltage Range in Backup
Vac
AC L-N Output Voltage Range in Backup
Vac
AC Frequency Range in Backup (min - nom - max)
Hz
Maximum Continuous Output Current in Backup Operation 12.5
16
25
32
42 43 A
32*
43*
GFDI
A
THD
%
OUTPUT
-
SMART EV CHARGER AC
Rated AC Power
W
AC Output Voltage Range
Vac
On-Grid AC Frequency Range (min - nom - max)
Hz
Maximum Continuous Output Current @240V (grid, PV and battery)
Aac
INPUT
-
DC
(
PV AND BATTERY
)
Transformer-less, Ungrounded
Max Input Voltage
Vdc
Nom DC Input Voltage
Vdc
Reverse-Polarity Protection
Ground-Fault Isolation Detection
INPUT
-
DC
(
PV
)
Maximum DC Power @ 240V 6000
7600
12000
15200
22000 22800 W
15200*
22800*
Maximum DC Power @ 208V
-
6600
10000
-
-
20000
W
Maximum Input Current
(5)
@ 240V 8.5
10.5
16.5
20
27 31 Adc
20*
31*
Maximum Input Current
(5)
@ 208V
-
9
13.5
-
-
27
Adc
Max. Input Short Circuit Current
Adc
Maximum Inverter Efficiency
99
99.2
%
CEC Weighted Efficiency
99
99 @ 240V
98.5 @ 208V
%
2-pole Disconnection
* Supported with PN SExxxxH-USMMxxxxxx or SExxxxH-USMNxxxxxx
(1) These specifications apply to inverters with part numbers SExxxxH-USSMxxxxx or SExxxxH-USSNxxxxxx and connection unit model number DCD-1PH-US-PxH-F-x
(2) For other regional settings please contact SolarEdge support
(3) Not designed for standalone applications and requires AC for commissioning. Backup functionality is only supported for 240V grid
(4) Rated AC power in Backup Operation are valid for installations with multiple inverters. For a single backup inverter operation, rated AC power in Backup is 90% of the value stated
(5) A higher current source may be used; the inverter will limit its input current to the values stated