Installation Manual

l CPU:Thecommunicationboardfirmwareversion
l Country:thecurrentcountrysetting
Server Communication Status
S e r v e r : L A N < S _ O K >
S t a t u s : < O K >
x x x x x x x x
< E R R O R M E S S A G E >
NOTE
If the connection method is CDMA (refered to as "Cellular" in the status screens) or GSM, the server
screen is replaced with the Cellular or GSM status screens (see Cellular Status on page 68 and
GSM Status on page 68).
l Server:ThemethodofconnectiontotheSolarEdgemonitoringplatform.
l S_OK:TheconnectiontotheSolarEdgemonitoringplatformissuccessful(shouldappearonlyiftheis
connectedtotheserver).
l Status:DisplaysOKiftheinverterestablishedsuccessfulconnectionandcommunicationwiththe
specifiedserverport/(LAN,RS485orZigBeecard).
l xxxxxxxx:Eight-bitEthernetcommunicationconnectionstatus:Astringof1sand0sisdisplayed.1
indicatesOK,0indicatesanerror.Foralistofthepossibleerrorsandhowtotroubleshootthem,refer
toCommunicationTroubleshootingonpage93.
l Error message,accordingtofailure.RefertoTroubleshootingonpage93.
IP Status
ThisscreendescribestheEthernetconfiguration:IP,Mask,GatewayandMACaddress(MediaAccess
Control)oftheInverter.
I P 1 9 2 . 1 6 8 . 2 . 1 1 9
M S K 2 5 5 . 2 5 5 . 2 5 5 . 0
G W 1 9 2 . 1 6 8 . 2 . 1
M A C 0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
Chapter 8: User Interface
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.3
67