SE9KUS Three Phase Inverter for 208V Grid DS-000034-NA
Three Phase Inverters for the 120/208V Grid
(1)
for North America
(1) For 277/480V inverters refer to: https://www.solaredge.com/sites/default/les/se-three-phase-us-inverter-277-480V-setapp-datasheet.pdf
(2) For other regional settings please contact SolarEdge support
(3) Where permitted by local regulations
(4) Field replacement kit for 1 pair of inputs P/N: DCD-3PH-1TBK; Field replacement kit for 3 pairs of fuses and holders P/N: DCD-3PH-6FHK-S1
(5) For power de-rating information refer to: https://www.solaredge.com/sites/default/les/se-temperature-derating-note-na.pdf
APPLICABLE TO INVERTERS
WITH PART NUMBER
SEXXK
-
XXXXXBXX4
MODEL NUMBER SE9KUS
OUTPUT
Rated AC Power Output 9000 VA
Maximum AC Power Output 9000 VA
Output Line Connections
3 phase, 3-wire / PE (L1-L2-L3), TN, TT
3 phase, 4-wire / PE (L1-L2-L3-N), TN, TT
AC Output Voltage Minimum-Nominal-Maximum
(2)
(L-N) 105-120-132.5 Vac
AC Output Voltage Minimum-Nominal-Maximum
(2)
(L-L) 183-208-229 Vac
AC Frequency Min-Nom-Max
(2)
59.3 - 60 - 60.5 Hz
Maximum Continuous Output Current (per Phase) 25 A
GFDI Threshold 1 A
Utility Monitoring, Islanding Protection, Country Congurable Set Points Yes
THD ≤ 3 %
INPUT
Maximum DC Power (Module STC) 12150 W
Transformer-less, Ungrounded Yes
Maximum Input Voltage DC to Gnd 250 Vdc
Maximum Input Voltage DC+ to DC-
500
Vdc
Nominal Input Voltage DC to Gnd 200 Vdc
Nominal Input Voltage DC+ to DC- 400 Vdc
Maximum Input Current 26.5 Adc
Maximum Input Short Circuit Current 45 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 1MΩ Sensitivity
(3)
CEC Weighted Efciency 96.5 %
Night-time Power Consumption < 3 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, Ethernet, Built-in Cellular (optional)
Inverter Commissioning With the SetApp mobile application using built-in access point for local connection
Rapid Shutdown – NEC 2014, 2017 and 2020 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect
RS485 Surge Protection Plug-in Supplied with the inverter
Smart Energy Management Export Limitation
STANDARD COMPLIANCE
Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)
Emissions FCC part15 class B
INSTALLATION SPECIFICATIONS
AC output conduit size / AWG range 3/4” minimum / 8-4 AWG
DC input conduit size / AWG range 3/4” minimum / 12-6 AWG
Number of DC inputs
(4)
2 pairs
Dimensions (H x W x D) 21 x 12.5 x 10.5 / 540 x 315 x 260
in /
mm
Dimensions with Safety Switch (H x W x D) 30.5 x 12.5 x 10.5 / 775 x 315 x 260
in /
mm
Weight 93.6 / 42.5 lb / kg
Weight with Safety Switch 100.3 / 45.5 lb / kg
Cooling Fans (user replaceable)
Noise < 55 dBA
Operating Temperature Range -40 to +140 / -40 to +60
(5)
˚F / ˚C
Protection Rating NEMA 3R
SE9KUS
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc.
All other trademarks mentioned herein are trademarks of their respective owners. Date: 04/2021 DS-000034-2.0-NA. Subject to change without notice.