SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US Units
Utility monitoring, islanding protection, country
configurable thresholds
Yes
INPUT
Maximum DC power (Module STC) 4050 5100 6750 8100 10250 W
Transformer-less, ungrounded Yes
Maximum input voltage 500 Vdc
Nominal DC input voltage 350 @240V
325 @208V / 350
@240V
350 @240V
Maximum input current
1
9.5 13
16.5 @208V
15.5 @240V
18 23 Adc
Maximum input short circuit current 45 Adc
Maximum input source back-feed current 0 A
Reverse-polarity protection Yes
Ground-fault isolation detection 600 kΩ Sensitivity
Maximum inverter efficiency 97.7 98.2 98.3 98.3 98 %
CEC weighted efficiency 97.5 98
97.5 @208V
98 @240V
97.5 97.5 %
Night time power consumption < 2.5 W
ADDITIONAL FEATURES
Supported communication interfaces RS485, Ethernet, ZigBee (optional), cellular (optional)