Installation Manual

Maintenance
Fromthemainmenu,selectMaintenancetoconfigurevarioussystemsettings,asdescribedbelow.
Maintenance
DateandTime
Sep-7 2017
09:45am
Temperature Celsius
ResetCounters
FactoryReset
ArcFaultCircuit
Interrupter(AFCI)
Enabled
Automatic
Reconnect
FirmwareUpgrade
Load/Save
Configuration
Diagnostics
StandbyMode Disable
GridProtection
BoardReplacement
l Date and Time:Settheinternalreal-timeclock.IfconnectedtotheSolarEdgemonitoringplatform,
thedateandtimearesetautomaticallyandonlytimezoneshouldbeset.
l Temperature:Setthetemperatureunitstouse:CelsiusorFahrenheit
l Reset Counters:ResetstheaccumulatedenergycountersthataresenttotheSolarEdgemonitoring
platform
l Factory Reset:Performsageneralresettothedefaultdevicesettings.
l Arc Fault Circuit Interrupter (AFCI):Enablesordisablesproductioninterruptionincaseofarc-fault,
setsthereconnectionmode,andenablesordisablesmanualAFCIself-test.
Refertohttp://www.solaredge.com/sites/default/files/arc_fault_detection_
application_note_na.pdf.
l Firmware Upgrade:Performasoftwareupgrade.
l Load / Save Configuration:Enablessavingorloadingsystemparametersfromone
invertertoanother.
Three Phase Inverter with synergy technology Guide MAN-01-00401-1.1
45