Specifications Sheet
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are
trademarks of their respective owners. Date: 08/2016. V.01. Subject to change without notice.
SolarEdge Cellular CDMA Kit
for Single Phase Inverters
North America
SE1000-CDMA2005
SE1000-CDMA2005 UNIT
FUNCTIONAL
Number of Inverters Monitored with a Single
CDMAKit
1
DataSamplingRate 15minutes
DataUploadRate Every four hours
Data Plan 5yearprepaidplan(non-extendable*)
Supported by Inverter Firmware CPUv3.12xxandabove
RF PERFORMANCE
OperangFrequencyMin.-Max.CDMA800 Modemtransmit:824-849,Modemreceive:869-894 MHz
OperangFrequencyMin.-Max.CDMA1900 Modemtransmit:1850-1910,Modemreceive:1930-1990 MHz
AntennaConnector RP-SMA
Maximumtransmitpower 24 dBm
ReceiverInputSensivity
(ForwardLinkRFLevel@FER<0.5%)
Typ.-107,Min.-106 dBm
STANDARD COMPLIANCE
Safety cUL,UL60950
EmissionsandRadio FCCparts15,22,24classB,IndustryCanada(IC):ICES-003,RSS-102
INSTALLATION SPECIFICATION
Dimensions(LxW) 3.55x1.35/90.5x34.5 in/mm
OperangTemperature -40to+185/-40to+85 °F/°C
*NewCDMAKitcanbepurchasedwhentheplanexpires
SolarEdge PortalCellular Tower
Inverter