Installation Manual
Chapter 3: Configuring Cellular Communication
CDMA Cellular Installation Guide - MAN-01-00194-1.3
18
6 Exit the Setup mode by selecting the Exit option in each
submenu screen, or wait for the inverter to automatically exit
Setup mode if no buttons are pressed for more than two
minutes.
Verifying the Connection
The modem communicates with the SolarEdge monitoring portal
every several hours and sends all monitoring data accumulated since
last communication.
1 Check the server communication status screen:
S e r v e r : C e l l < S _ O K >
S t a t u s : <OK>
S i g : 5
< E r r o r m e s s a g e >
Server: The method of communication to the SolarEdge
monitoring portal. Should display Cell.
Status: Displays OK if the inverter established a successful
physical connection to the Cellular modem.
S_OK: The last communication to the SolarEdge
monitoring portal was successful (appears if the inverter
is connected to the portal). If S_OK is not displayed, refer
to Troubleshooting, on page 19).
Sig: The signal strength, received from the cellular
modem. A value between 0-5, (0 = no signal, 5 = excellent
signal).
Error message per communication connection status
failure (Refer to Troubleshooting, on page 19).
2 Close the inverter cover as described in its manual. Verify
proper cover fastening to ensure sealing.