Installation Guide

D e v P r o t # #
R S 4 8 5 - 1 < M T R > < W N > < 1 >
R S 4 8 5 - 2 < - - - > < - - > < - - >
Z i g B e e < - - - > < - - > < - - >
Dev: the type of device connected to this port. MTR indicates a meter.
Prot: the communication protocol
## = 1: Indicates that the connection to the meter is successful.
4.
Continue pressing the Enter button or the LIGHT button using short presses until
reaching the meter status screen showing the Energy [Wh] total. If there is more
than one meter/ function, there is a status screen for each one. The following is an
example of an Export meter:
E x p o r t M e t e r
S t a t u s : < O K / E r r o r # >
P o w e r [ W ] : x x x x x . x
E n e r g y [ W h ] : x x x x x . x
Status: Displays the state of communications between the meter and the inverter.
Displays 'OK' if the meter is communicating with the inverter.
<Error message>: If an internal meter error occurs, it will be displayed here.
Refer to
Troubleshooting the Meter
on page 29.
Power [W]: Displays the exported or imported power.
Energy [Wh]: Displays the total energy read by the meter.
Energy Meter with Modbus Connection MAN-01-00270-1.3
28 Device Configuration