Install Manual
Appendix D: Meter Technical Specifications
SE-MTR240-2-200-S1
SE-MTR240-2-400-S1
UNITS
ELECTRICAL SERVICE
Operating Voltage Range - Line to Line 211 - 264 Vac
AC Frequency 60 Hz
Grids Supported L1 / L2 / N / PE
Power Consumption (typ.) 1.2 W
COMMUNICATION
Supported Communication Interfaces RS485
Response time ≤1 sec
Device ID (Modbus) 2
ACCURACY (@ 77°F / 25°C, PF:0.7- 1)
1% - 100% of Rated CT Current ±1 %
CURRENT TRANSFORMERS
Rated RMS current
1
200 400
Dimensions (Internal ; External)
0.8 x 0.8 ; 2.4 x 2.4 /
20 x 20 ; 61 x 61
1.26 x 1.83 ; 3.3 x 4.5 / 32 x
46.5 ; 83.4 x 114
in/mm
STANDARD COMPLIANCE
Safety UL1741
INSTALLATION SPECIFICATIONS
Dimensions (HxWxD) 8.1 x 12.4 x 4.6 / 206.6 x 316 x 117.5 in / mm
Weight 3.9 / 1.8 lb / gm
Enclosure type High impact, ABS and/or ABS/PC plastic UL 94V-0, IEC FV-0
Operating Temperature Range -22 to +131 / -30 to + 55 °F / °C
Relative Humidity (noncondensing) 5 - 90 %
Protection Rating NEMA Type 3R
Conduit Entry Diameters 0.75 or 1/ 19 or 25 in / mm
Mounting Type Wall mount
1
For other ratings contact SolarEdge
Appendix D: Meter Technical Specifications
SolarEdge-SolarEdge Electricity Meter Installation Guide MAN-01-00270-1.0
23