Install Manual
6.
SelectDevice Type.thefollowingscreenisdisplayed:
S o l a r E d g e < M >
N o n - S E L o g g e r < S >
R e v e n u e M e t e r < M >
M u l t i - d e v i c e s < M >
N o n e
7. SelectRevenue Meter,thefollowingscreenisdisplayed:
D e v i c e T y p e < M T R >
P r o t o c o l < W N >
D e v i c e I D < 1 >
C T R a t i n g < 0 >
M e t e r F u n c . < N o n e >
8.
Configurethemeterparametersasfollows:
l SelectProtocol è WattNode.
l SelectDevice ID: 2
l SettheCTratingtothevaluethatappearsontheCT:CT Rating è <xxxxA>.Thedefaultis5
Amperes.Ifthedisplayedratingis0oryoucannotchangethevalue,thereisnocommunication
withthemeter.CheckthattheACpowertothemeterison.
l SelectMeter Func. andselectoneofthefunctionalityoptions,accordingtotheinstalledmeter
specificationsandlocation.
E x p o r t + I m p o r t
E x p o r t
C o n s u m p t i o n
P r o d u c t i o n
I m p o r t
N o n e
o
Export+Import:Themeterisinstalledatthegridconnectionpointandreadspulsesfromboth
directions-exportandimportenergy.
o
Export:Themeterisinstalledatthegridconnectionpointandreadstheexportenergy.
o
Consumption:Themeterisinstalledattheloadconsumptionpointandreadstheenergy
consumedbythesite.
o
Production:Themeterisinstalledattheinverteroutputandreadstheenergyproducedby
theinverter.
o
Import:Themeterisinstalledatthegridconnectionpointandreadstheimportenergy.
o
None:Noreading
TheselectedoptionisdisplayedintheRS485Confscreenas<E+I>,<E>,<Cons>,<Prod>,<I>,
<None>.
9.
ExitSetupmode.
NOTE
Calculated meter readings, such as self-consumption, are calculated using the data measured by
the meter and the inverters. Calculated meters are only sent when Energy Manager is enabled
(for details refer to http://www.solaredge.us/files/pdfs/products/export_limitation_application_
note_NA.pdf).
Chapter 3: SolarEdge Device Configuration
SolarEdge-SolarEdge Electricity Meter Installation Guide MAN-01-00270-1.0
13