Installation Manual
Verifying the Connection
1.
Checktheservercommunicationstatusscreen:
S e r v e r : C e l l < S _ O K >
S t a t u s : < O K >
M N O : < x x x x x x x > S i g : 5
< E r r o r m e s s a g e >
l Server:ThemethodofcommunicationtotheSolarEdgemonitoring
portal.ShoulddisplayCell.
l Status:DisplaysOKiftheinverterestablishedasuccessfulphysical
connectiontotheGSMmodem.
l S_OK:ThelastcommunicationtotheSolarEdgemonitoringportal
wassuccessful.IfS_OKisnotdisplayed,refertoTroubleshooting
below.
l MNO:Themobilenetworkoperatorname
l Sig:Thesignalstrength,receivedfromtheGSMmodem.Avalue
between0-5,(0=nosignal,5=excellentsignal).
l Error messagepercommunicationconnectionstatusfailure(Referto
Troubleshootingbelow).
2. Closetheinvertercoverasdescribedinitsmanual.Verifypropercover
fasteningtoensuresealing.
Troubleshooting
The Inverter is not Starting Up
Iftheinverterisnotstartingup,themodemmayhavebeeninstalledinan
inverterwithanincompatibleCPUsoftwareversion.
Checkifthemodemisinstalled,removeitandupgradetheinverteras
describedinSystem Compatibility Check and Upgradeonpage6.
Chapter 4: Configuring GSM Communication
GSM Installation Guide MAN-01-00248-1.1
21