Chapter 8: Errors and Troubleshooting
For the following system errors, when an error occurs, the red LEDring lights ON and
the buzzer beeps 10 times.
The error messages are displayed on the mobile app screen.
If the error persists- contact SolarEdge Support.
Error code Displayed Error message Description and Troubleshooting
3x85 EVSEComm. Error
An internal communication error.
When this error occurs, the red
LEDring is not lit, the buzzer does
not beep and charging is not
affected.
Check that the internal connections
on the communication board are
properly done.
1Cx1; 1Cx8
Over Current
Press Charge Now
Smart EVCharger AC over current.
Press the Charge Now push
button on the Smart EV Charger,
see
Figure 2
-or-
Tap Charge Now on the Smart EV
Charger tab of the Monitoring
App
1Cx2; 1xC9
Over Voltage
Press Charge Now
Smart EVCharger ACvoltage too
high.
Press the Charge Now push
button on the Smart EVCharger,
see
Figure 2
-or-
Tap Charge Now on the Smart EV
Charger tab of the Monitoring
App
1Cx3,Cx14;
1Cx15
Ground Fault (RCD)
Press Charge Now
Smart EVCharger ground fault
detected.
Chapter 8: Errors and Troubleshooting 46
Smart EV Charger Installation MAN-01-00657-1.0