Install Manual

Table Of Contents
Connecting the AC cable between the Single phase inverter
with HD-Wave technology and the Smart EV Charger
Figure 8: Single phase inverter with HD-Wave technology connected to Smart EV Charger
To connect the AC cable between the Single phase inverter with HD-Wave
technology and the Smart EV Charger:
1.
Disconnect the AC plug from the bottom of the Smart EV Charger. See
Disconnecting the AC Plug
on page 26
2. Insert the AC cable that contains the L1, L2 and grounding wires through the
opened conduit on the side of the DC Safety Unit.
3. Connect the AC wires according to the labels on the terminal block (see the
following figure).
Smart EV Charger Installation MAN-01-00657-1.0
33 Connecting the Smart EV Charger to the Single phase inverter with
HD-Wave technology