Install Manual

Table Of Contents
Connecting the Smart EV Charger to the Single phase
inverter with HD-Wave technology
This section describes the procedures required for connecting the Smart EVCharger to
the Single phase inverter with HD-Wave technology. This option enables using PV
produced by the Single phase inverter with HD-Wave technology as well as power from
the grid, for Level 2 EV charging.
Prerequisites
Before connecting the Smart EVCharger to the Single phase inverter with HD-Wave
technology, replace the bus bar and AC terminal blocks inside the DC Safety Unit as
described in these following procedures, using the supplied kit.
Kit Contents
2 terminal blocks
9 hole bus bar
Required Equipment
Unibit drill
Open ended 36mm wrench
3.6" / 5mm flat-blade screwdriver
Main Procedure
1. Remove the DC Safety Unit Cover and open the AC conduit drill guide
2. Replace the existing AC terminal blocks, inside the DC Safety Unit
3. Replace the existing bus bar, inside the DC Safety Unit
4. Connect the AC cable between the Single phase inverter with HD-Wave technology
and the Smart EV Charger
5. Connect the AC wires to the DC Safety Unit AC terminals
The following are the detailed procedures.
Smart EV Charger Installation MAN-01-00657-1.0
29 Connecting the Smart EV Charger to the Single phase inverter with
HD-Wave technology