Install Manual
Table Of Contents
- Disclaimers
- Revision History
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- RISK OF FIRE AND ELECTRIC SHOCK PREVENTION IMPORTANT SAFETY INSTRUCTIONS
- Smart EV Charging Safety Instructions
- Chapter 1: Introduction to Smart EV Charger
- Chapter 2: Connectors and Interfaces
- Chapter 3: Configuring and Using Smart EV Charger with mySolarEdge
- Chapter 4: Charging Instructions
- Chapter 5: Professional Installer- Connecting the AC Directly to the Smart EV Charger
- Required Equipment
- Main Procedure
- Grid Connection Guidelines
- Setting the Circuit Breaker Ratings
- Supported AC Grids
- Removing the Smart EV Charger Covers
- Disconnecting the AC Plug
- Directly Connecting the AC Grid to the Smart EV Charger
- Connecting the Smart EV Charger to the Single phase inverter with HD-Wave tec...
- Closing the Smart EV Charger Covers
- Chapter 6: Professional Installer - Setting Up Communication
- Chapter 7: Processional Installer - Configuring and Using Smart EV Charger with SetApp
- Chapter 8: Errors and Troubleshooting
- Appendix A: Professional Installer - Connecting the Smart EV Charger to an Energy Meter
- Mechanical Specifications
- Technical Specifications - Smart EV Charger (North America)
- Support Contact Information
4. Release the gland nut. See
Figure 6
.
5. Pull out the AC Plug cable from the conduit entry. See
Figure 6
.
Directly Connecting the AC Grid to the Smart EV
Charger
To directly connect the AC grid to the Smart EV Charger:
1. Strip 15/32'' (12mm) of the 14-6 AWG AC wire insulation.
2.
Connect the conduit ground with a 14-6 AWG wire to the GND (see the figure in
step 5).
3. Insert the AC conduit into the AC conduit entry.
NOTE
Connect the equipment grounding before connecting the AC wires to the AC
terminal block.
Veillez à relier le conducteur de PE (la terre) avant de connecter les fils CA au
bornier CA.
4.
Insert the AC cable through the conduit entry and tighten the screws (see the figure
in step 5).
5.
Insert the wires into the round openings according to the labels on the terminal
blocks (G, L2 and L1) and close the levers – the wires are automatically clamped (see
the following figure).
Smart EV Charger Installation MAN-01-00657-1.0
27 Directly Connecting the AC Grid to the Smart EV Charger