WARNING!
Before changing the DIP Switches, turn off the ACto the Smart EV Charger.
AVERTISSEMENT!
Avant de changer les commutateurs DIP, coupez l'alimentation CA du chargeur
Smart EV.
Figure 4: Smart EV Charger DIP switch interface
To set the circuit breaker ratings:
Adjust the Smart EV Charger DIP switches according to your circuit breaker rating to set
maximum allowed AC current from the grid.
By default, the DIP switch is set to the 40A which is the maximum allowed AC current.
Circuit Breaker Rating
DIPSwitch
Settings
Maximum
Allowed
AC Current
from Grid
Wire Gauge Range
SW1 SW1
20 A OFF OFF 16 A 14-6 AWG
30 A ON OFF 24 A 10-6 AWG
40 A OFF ON 32 A 8-6 AWG
50 A ON ON 40 A 8-6 AWG