Install Manual

Table Of Contents
Chapter 5: Professional Installer- Connecting
the AC Directly to the Smart EVCharger
It is recommended to use this connection option for outdoor installations in case an AC
socket is not accessible indoors. This option enables you to connect the Smart EV
charger directly to a service panel.
Required Equipment
Open ended 36 mm wrench
Allen Key
Screwdriver
Main Procedure
1.
Set the circuit breaker rating DIP switches
2. Remove the Smart EV Charger covers
3. Disconnect the AC Plug
4. Directly connect the AC to the Smart EV Charger
5. Close the Smart EV Charger
Grid Connection Guidelines
The conduits, hubs and fittings must be suited for field wiring systems.
Use only copper conductors rated for a minimum of 167°F.
Use the conduit and wiring appropriate for the installation location per the NEC.
Outdoor installations must use components that are rated NEMA 3R or higher.
NOTE
For more wiring information refer to the
SolarEdge
Recommended AC Wiring Application Note
, available on the
SolarEdge website at
https://www.solaredge.com/sites/default/files/application-
note-recommended-wiring.pdf
Setting the Circuit Breaker Ratings
DIPSwitches
Set the circuit breaker rating DIP switches as shown in the following figure and table.
Chapter 5: Professional Installer- Connecting the AC Directly to the Smart
EVCharger 22
Smart EV Charger Installation MAN-01-00657-1.0