Specifications Sheet

Power Optimizer for North America
P730 / P800p / P850
PV SYSTEM DESIGN USING A SOLAREDGE INVERTER

THREE PHASE 208V 
CompablePowerOpmizers P730
(5)
P800p,P850
(5)
P730 P800p,P850
MinimumStringLength
PowerOpmizers 8 13
PVModules 16 26
MaximumStringLength
PowerOpmizers 30 30
PVModules 60 60
MaximumPowerperString 6000
(6)
7200 12750
(7)
15300 W
ParallelStringsofDierentLengthsorOrientaons Yes




P800p





INPUT
RatedInputDCPower
(1)
730 800 850 W
AbsoluteMaximumInputVoltage
(Vocatlowesttemperature)
125 83 120 Vdc
MPPTOperangRange 12.5-105 12.5-83 12.5-105 Vdc
MaximumShortCircuitCurrent(Isc) 11 14 12.5 Adc
MaximumDCInputCurrent 13.75 17.5 15.63 Adc
MaximumEciency 99.5 %
WeightedEciency 98.6 %
OvervoltageCategory II

MaximumOutputCurrent 15 18 Adc
MaximumOutputVoltage 85 Vdc

SafetyOutputVoltageperPowerOpmizer 1±0.1 Vdc

EMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3
Safety IEC62109-1(classIIsafety),UL1741
Material UL-94(5-VA),UVResistant
RoHS Yes

CompableSolarEdgeInverters Threephaseinverters
MaximumAllowedSystemVoltage 1000 Vdc
Dimensions(WxLxH) 128x152x50/5x5.97x1.96
128x158x59/
5x6.22x2.32
128x152x59/
5x5.97x2.32
mm
/in
Weight(includingcables) 1064/2.34 1090/2.4 1064/2.34 gr/lb
InputConnector MC4Compable
OutputWireType/Connector DoubleInsulated;MC4Compable
OutputWireLength 2.1/6.9 1.8/5.9 2.1/6.9 m/
OperangTemperatureRange
(2)
-40-+85/-40-+185 ˚C/˚F
ProteconRang IP68/NEMA6P
RelaveHumidity 0-100 %
(3)
P800pandP850canbemixedinonestring.ItisnotallowedtomixP730withP800p/P850inonestringortomixP730/P800p/P850withP300/P320/P400/P405inonestring.
(4)
InacaseofoddnumberofPVmodulesinonestringitisallowedtoinstalloneP730/P800p/P850poweroptimizerconnectedtoonePVmodule.WhenconnectingasinglemoduletotheP800psealtheunused
inputconnectorswiththesuppliedpairofseals.
(5)
P730/P800p/P850designwiththreephase208Vinvertersislimited.UsetheSolarEdgeSiteDesignerforverification.
(6)
ForSE14.4KUS/SE43.2KUS:Itisallowedtoinstallupto6,500Wperstringwhen3stringsareconnectedtotheinverter(3stringsperunitforSE43.2KUS)andwhenthemaximumpowerdifferencebetweenthe
stringsisupto1,000W.
(7)
ForSE30KUS/SE33.3KUS/SE66.6KUS/SE100KUS:Itisallowedtoinstallupto15,000Wperstringwhen3stringsareconnectedtotheinverter(3stringsperunitforSE66.6KUS/SE100KUS)andwhenthemaximum
powerdifferencebetweenthestringsisupto2,000W.
*P850replacedtheP800s;theycanbeusedinterchangeablyandcanbeconnectedinthesamestring.
(1)
RatedSTCpowerofthemodule.Moduleofupto+5%powertoleranceallowed.
(2)
Forambienttemperatureabove+70˚C/+158˚Fpowerde-ratingisapplied.RefertoPowerOptimizersTemperatureDe-RatingApplicationNoteformoredetails.
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein
are trademarks of their respective owners. Date: 07/2018/V01/ENG NA. Subject to change without notice.