Site Manager Manual

24
SolarEdge Site Designer V2.3
Edit System Design
In the Design screen you can design any system, and receive immediate
verification of the design. This option should be used if there is no
recommended design or if you do not want to use one of the recommended
designs because of specific design constraints.
When choosing the Edit Design option, the screen shows the design you
chose in the Get Design screen. You then build and verify a design as
detailed below and shown in Figure 16.
Figure 16 Edit Design
1 Choose a different Optimizer configuration.
2 Adjust the maximum DC/AC sizing.
3 Germany only: If the system size is <30kWp, this checkbox appears.
This allows you to get designs with an AC/DC ratio according to EEG
2012.
4 Choose a different Inverter model.
5 Change the quantity of inverters of a given model.
6 View the permitted string lengths for the chosen power optimizer
configuration and inverter model.