P730 Power Optimizer Specifications
Power Optimizer For North America
P730 / P850 / P800p
Optimizer Model
(Typical Module Compatibility)
P730
(for 2 x high power 72-cell PV
modules)
P850*
(for 2x high power or bi-facial
modules)
P800p
(for 2x 96-cell 5’’ PV modules)
INPUT
Rated Input DC Power
(1)
730 850 800 W
Connection type Single input for series connected modules
Dual input for independently connected
modules
Absolute Maximum Input Voltage
(Voc at lowe temperature)
125 120 83 Vdc
MPPT Operating Range 12.5 - 105 12.5 - 83 Vdc
Maximum Short Circuit Current (Isc) 11 12.5 14 Adc
Maximum Short Circuit Current per input (Isc) N/A 7 Adc
Maximum DC Input Current 13.75 15.63 17.5 Adc
Maximum DC Input Current per input N/A 8.75 Adc
Maximum Eciency 99.5 %
Weighted Eciency 98.6 %
Overvoltage Category II
OUTPUT DURING OPERATION
(
POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current 15 18 Adc
Maximum Output Voltage 85 Vdc
OUTPUT DURING STANDBY (
POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF
)
Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc
STANDARD COMPLIANCE
Photovoltaic Rapid Shutdown Syem Compliant with NEC 2014, 2017
(2)
EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety), UL1741
Material UL94 V-0, UV Resiant
RoHS Yes
INSTALLATION SPECIFICATIONS
Compatible SolarEdge Inverters Three phase inverters
Maximum Allowed Syem Voltage 1000 Vdc
Dimensions (W x L x H) 129 x 153 x 49.5 / 5.1 x 6 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 129 x 168 x 59 / 5.1 x 6.6 x 2.3 mm / in
Weight (including cables) 1064 / 2.34 1090 / 2.4 1064 / 2.34 gr / lb
Input Connector
(3)
MC4 MC4 Dual Input
(4)
Output Wire Type / Connector Double Insulated; MC4
Output Wire Length 2.1 / 6.9 1.8 / 5 2.1 / 6 m / ft
Operating Temperature Range
(5)
-40 - +85 / -40 - +185 ˚C / ˚F
Protection Rating IP68 / NEMA6P
Relative Humidity 0 - 100 %
(1)
Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed.
(2)
NEC 2017 requires max combined input voltage be not more than 80V.
(3)
For other connector types please refer to: https://www.solaredge.com/sites/default/les/optimizer-input-connector-compatibility.pdf.
(4)
In a case of odd number of PV modules in one ring it is allowed to inall one P730/P800p/P850 power optimizer connected to one PV module. When connecting a single module to
the P800p seal the unused input connectors with the supplied pair of seals.
(5)
For ambient temperature above +70˚C / +158˚F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Application Note for more details.
PV Syem Design Using a Solaredge Inverter
(6)
Three Phase 208V Three Phase 480V
Compatible Power Optimizers P730
(7)
P800p, P850
(7)
P730 P800p, P850
Minimum String Length
Power Optimizers 8 13
PV Modules 16 26
Maximum String Length
Power Optimizers 30 30
PV Modules 60 60
Maximum Power per String 6000
(8)
7200 12750
(9)
15300 W
Parallel Strings of Dierent Lengths or Orientations Ye s
(6)
P800p and P850 can be mixed in the same ring. It is not allowed to mix P730 with P800p/P850 in one ring or to mix P730/P800p/P850 with P300/P320/P400/P405 in one ring.
(7)
P730/ P800p/ P850 design with three phase 208V inverters is limited. Use the SolarEdge Designer for verication.
(8)
For SE14.4KUS/SE43.2KUS: It is allowed to inall up to 6,500W per ring when 3 rings are connected to the inverter (3 rings per unit for SE43.2KUS) and when the maximum power dierence between the
rings is up to 1,000W.
(9)
For SE30KUS/SE33.3KUS/SE66.6KUS/SE100KUS: It is allowed to inall up to 15,000W per ring when 3 rings are connected to the inverter (3 rings per unit for SE66.6KUS/SE100KUS) and when the
maximum power dierence between the rings is up to 2,000W.
* P850 replaced the P800s; they can be used interchangeably and can be connected in the same ring.
© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or regiered trademarks of SolarEdge Technologies, Ltd.