Specifications
SolarEdge Power Optimizer Module Add-On For
Commercial Installations P600 / P700 / P800p / P800s
PV SYSTEM DESIGN USING A SOLAREDGE
INVERTER
AND LARGER
AND LARGER
CompablePowerOpmizers P600 P600,P700 P800 P600,P700 P800
MinimumStringLength
PowerOpmizers 13 12 13
PVModules 26 24 26
MaximumStringLength
PowerOpmizers 30
PVModules 60
MaximumPowerperString 11250
(7)
13500
12750
(8)
15300
W
ParallelStringsofDierentLengthsorOrientaons Yes
PV modules)
(for 2 x 72-cell
PV modules)
2x high power or bi-facial
modules)
INPUT
RatedInputDCPower
(1)
600 700 800 W
AbsoluteMaximumInputVoltage
(Vocatlowesttemperature)
96 125 83 120 Vdc
MPPTOperangRange 12.5-80 12.5-105 12.5-83 12.5-105 Vdc
MaximumShortCircuitCurrent(Isc) 10.1 14 12.5 Adc
MaximumEciency 99.5 %
WeightedEciency 98.6 %
OvervoltageCategory II
MaximumOutputCurrent 15 18 Adc
MaximumOutputVoltage 85 Vdc
SafetyOutputVoltageperPowerOpmizer 1 Vdc
EMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3
Safety IEC62109-1(classIIsafety)
RoHS Yes
FireSafety VDE-AR-E2100-712:2013-05
CompableSolarEdgeInverters
Threephaseinverters
SE15K&larger
Threephaseinverters
SE16K&larger
MaximumAllowedSystemVoltage 1000 Vdc
Dimensions(WxLxH)
128x152x43/
5x5.97x1.69
128x152x50/
5x5.97x1.93
128x152x59/5x5.97x2.32 mm/in
Weight(includingcables) 834/1.8 933/2.1 1019/2.2 1064/2.3 gr/lb
InputConnector
(2)
MC4 MC4(SingleorDualinput)
(6)
MC4
OutputConnector MC4
OutputWireLength
1.2/3.9(portrait
orientaon)or
1.8/5.9(landscape
orientaon)
1.2/3.9(portrait
orientaon)or
2.1/6.9(landscape
orientaon)
1.2/3.9(portrait
orientaon)or
1.8/5.9(landscape
orientaon)
(4)
1.2/3.9(portrait
orientaon)or
2.1/6.9(landscape
orientaon)
m/
OperangTemperatureRange
(3)
-40-+85/-40-+185 ˚C/˚F
ProteconRang IP68/NEMA6P
RelaveHumidity 0-100 %
(1)
RatedSTCpowerofthemodule.Moduleofupto+5%powertoleranceallowed.
(2)
ForotherconnectortypespleasecontactSolarEdge.
(3)
Forambienttemperatureabove+70˚C/+158˚Fpowerde-ratingisapplied.RefertoPowerOptimizersTemperatureDe-RatingApplicationNoteformoredetails.
(4)
Singleinputversionhas1.8moutputwires.
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein
are trademarks of their respective owners. Date: 04/2017. V.01. Subject to change without notice.
(5)
P600andP700canbemixedinonestring.ItisnotallowedtomixP600/P700/P800withP300/P350/P500/P404/P405inonestring.
(6)
InacaseofoddnumberofPVmodulesinonestringitisallowedtoinstalloneP600/P700/P800poweroptimizerconnectedtoonePVmodule.WhenconnectingasinglemoduletotheP800pthesingle
inputversionshouldbeused.
(7)
ForSE27.6K:Itisallowedtoinstallupto13,500Wperstringwhen3stringsareconnectedtotheinverterandwhenthemaximumpowerdifferencebetweenthestringsisupto2,000W;invertermaxDC
power:37,250W.
(8)
ForSE33.3K:Itisallowedtoinstallupto15,000Wperstringwhen3stringsareconnectedtotheinverterandwhenthemaximumpowerdifferencebetweenthestringsisupto2,000W;invertermaxDC
power:45,000W.