Module Add-On P320-P505 Datasheet

OPTIMIZER MODEL

P320
(for high-power

P370
(for higher-power
60 and 72-cell

P400
(for 72 & 96-cell

P405


P505
(for higher

INPUT
RatedInputDCPower
(1)
320 370 400 405 505 W
AbsoluteMaximumInputVoltage
(Vocatlowesttemperature)
48 60 80 125 83 Vdc
MPPTOperangRange 8-48 8-60 8-80 12.5-105 12.5-83 Vdc
MaximumShortCircuitCurrent(Isc) 11 10.1 14 Adc
MaximumDCInputCurrent 13.75 12.63 17.5 Adc
MaximumEciency 99.5 %
WeightedEciency 98.8 98.6 %
OvervoltageCategory II

MaximumOutputCurrent 15 Adc
MaximumOutputVoltage 60 85 Vdc

SafetyOutputVoltageperPower
Opmizer
1±0.1 Vdc

EMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3
Safety IEC62109-1(classIIsafety),UL1741
RoHS Yes

MaximumAllowedSystemVoltage 1000 Vdc
Compableinverters AllSolarEdgeSinglePhaseandThreePhaseinverters
Dimensions(WxLxH) 128x152x28/5x5.97x1.1
128x152x36/
5x5.97x1.42
128x152x50/
5x5.97x1.96
128x152x59/
5x5.97x2.32
mm/in
Weight(includingcables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/lb
InputConnector MC4
(2)
OutputWireType/Connector DoubleInsulated;MC4
OutputWireLength 0.95/3.0 1.2/3.9 m/
OperangTemperatureRange -40-+85/-40-+185 ˚C/˚F
ProteconRang IP68/NEMA6P
RelaveHumidity 0-100 %
(1)
RatedSTCpowerofthemodule.Moduleofupto+5%powertoleranceallowed.
(2)
ForotherconnectortypespleasecontactSolarEdge
SolarEdge Power Optimizer
Module Add-On for North America
P320 / P370 / P400 / P405 / P505





  
MinimumStringLength
(PowerOpmizers)
P320,P370,P400 8 10 18
P405/P505 6 8 14
MaximumStringLength
(PowerOpmizers)
25 25 50
(5)
MaximumPowerperString
5700(6000with
SE7600H-US,
SE10000H-US)
5250 6000 12750 W
ParallelStringsofDierentLengths
orOrientaons
Yes
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are
trademarks of their respective owners. Date: 03/2018/V01/ENG NAM. Subject to change without notice.
(3)
Fordetailedstringsizinginformaonreferto:hp://www.solaredge.com/sites/default/les/string_sizing_na.pdf.
(4)
ItisnotallowedtomixP405/P505withP320/P370/P400/P600/P700/P800inonestring.
(5)
Astringwithmorethan30opmizersdoesnotmeetNECrapidshutdownrequirements;safetyvoltagewillbeabovethe30Vrequirement