Module Add-On P320-P505 Datasheet
OPTIMIZER MODEL
P320
(for high-power
P370
(for higher-power
60 and 72-cell
P400
(for 72 & 96-cell
P405
P505
(for higher
INPUT
RatedInputDCPower
(1)
320 370 400 405 505 W
AbsoluteMaximumInputVoltage
(Vocatlowesttemperature)
48 60 80 125 83 Vdc
MPPTOperangRange 8-48 8-60 8-80 12.5-105 12.5-83 Vdc
MaximumShortCircuitCurrent(Isc) 11 10.1 14 Adc
MaximumDCInputCurrent 13.75 12.63 17.5 Adc
MaximumEciency 99.5 %
WeightedEciency 98.8 98.6 %
OvervoltageCategory II
MaximumOutputCurrent 15 Adc
MaximumOutputVoltage 60 85 Vdc
SafetyOutputVoltageperPower
Opmizer
1±0.1 Vdc
EMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3
Safety IEC62109-1(classIIsafety),UL1741
RoHS Yes
MaximumAllowedSystemVoltage 1000 Vdc
Compableinverters AllSolarEdgeSinglePhaseandThreePhaseinverters
Dimensions(WxLxH) 128x152x28/5x5.97x1.1
128x152x36/
5x5.97x1.42
128x152x50/
5x5.97x1.96
128x152x59/
5x5.97x2.32
mm/in
Weight(includingcables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/lb
InputConnector MC4
(2)
OutputWireType/Connector DoubleInsulated;MC4
OutputWireLength 0.95/3.0 1.2/3.9 m/
OperangTemperatureRange -40-+85/-40-+185 ˚C/˚F
ProteconRang IP68/NEMA6P
RelaveHumidity 0-100 %
(1)
RatedSTCpowerofthemodule.Moduleofupto+5%powertoleranceallowed.
(2)
ForotherconnectortypespleasecontactSolarEdge
SolarEdge Power Optimizer
Module Add-On for North America
P320 / P370 / P400 / P405 / P505
MinimumStringLength
(PowerOpmizers)
P320,P370,P400 8 10 18
P405/P505 6 8 14
MaximumStringLength
(PowerOpmizers)
25 25 50
(5)
MaximumPowerperString
5700(6000with
SE7600H-US,
SE10000H-US)
5250 6000 12750 W
ParallelStringsofDierentLengths
orOrientaons
Yes
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are
trademarks of their respective owners. Date: 03/2018/V01/ENG NAM. Subject to change without notice.
(3)
Fordetailedstringsizinginformaonreferto:hp://www.solaredge.com/sites/default/les/string_sizing_na.pdf.
(4)
ItisnotallowedtomixP405/P505withP320/P370/P400/P600/P700/P800inonestring.
(5)
Astringwithmorethan30opmizersdoesnotmeetNECrapidshutdownrequirements;safetyvoltagewillbeabovethe30Vrequirement