P400 Installation
Table Of Contents
- SolarEdge Installation Guide - North America Version 4.0
- Disclaimers
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimizers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Commissioning the Installation
- Chapter 6: User Interface
- Chapter 7: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Technical Specifications
- Appendix C: Mechanical Specifications
- Appendix D: External Fan Maintenance and Replacement
- Appendix E: Replacing and Adding System Components
- Appendix F: Inverter Arc Detection and Interruption
NOTE
If a revenue grade meter is connected to your inverter, it uses the RS485 port and
therefore an RS485 communication bus cannot be created.
ThefollowingsectionsdescribehowtophysicallyconnecttheRS485busandhowtoconfigure
thebus.
To connect the RS485 communication bus:
1. RemovetheinvertercoverasdescribedinRemoving the Inverter Coveronpage73
2. Removethesealfromoneoftheopeningsincommunicationgland#2andinsertthewire
throughtheopening.
3. Pulloutthe9-pinRS485/RS232terminalblockconnector,asshownbelow:
Figure 38: The RS485 terminal block
4. LoosenthescrewsofpinsA(+),B(-),andGontheleftoftheRS485terminalblock.
Figure 39: RS485/RS232 terminal block
5. InsertthewireendsintotheG, AandBpinsshownabove.UseFour-orsix-wiretwisted
paircableforthisconnection.YoucanuseanycolorwireforeachoftheA,BandG
connections,aslongasthesamecolorwireisusedforallApins,thesamecolorforallB
SolarEdge-Installation Guide MAN-01-00002-4.0
78
Creating an RS485 Bus Connection