Communication Connectors
Twocommunicationglandsareusedforconnectionofthevariouscommunicationoptions.
Eachglandhasthreeopenings.Thetablebelowdescribesthefunctionalityofeachopening.
Unusedopeningsshouldremainsealed.
Gland# Opening Functionality Cable Size (diameter)
1 (PG16)
One small External antenna cable 2-4 mm
Two large
Ethernet connection (CAT5/6),
ZigBee, CDMA
4.5-7 mm
2 (PG13.5) All three RS485, power reduction 2.5-5 mm
Figure 32: Communication Glands
ThecommunicationboardhasastandardRJ45terminalblockforEthernetconnection,a9-pin
terminalblockforRS485connection,asshownbelow:
Figure 33: Internal connectors
SolarEdge-Installation Guide MAN-01-00002-4.0