P400 Installation
Table Of Contents
- SolarEdge Installation Guide - North America Version 4.0
- Disclaimers
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimizers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Commissioning the Installation
- Chapter 6: User Interface
- Chapter 7: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Technical Specifications
- Appendix C: Mechanical Specifications
- Appendix D: External Fan Maintenance and Replacement
- Appendix E: Replacing and Adding System Components
- Appendix F: Inverter Arc Detection and Interruption
Status Screens - Operational Mode
DuringnormaloperationpressingtheexternalLCDlightbuttonturnsontheLCDbacklight.
Additionalpressesdisplaythefollowingscreensoneaftertheother.
Initial Status
V a c [ V ] V d c [ V ] P a c [ W ]
2 4 0 . 7 3 7 1 . 9 2 3 4 9 . 3
P _ O K : X X X / Y Y Y < S _ O K >
- - - - - - - - - - - - - - - - O N
l Vac [V]:TheACoutputvoltage
l Vdc [V]:TheDCinputvoltage
l Pac [W]:TheACoutputpower
l P_OK: XXX/YYY:Thereisaconnectiontothepoweroptimizersandatleastonepower
optimizerissendingmonitoringdata.XXXisthenumberofpoweroptimizersforwhich
telemetrieshavebeenreceivedinthelasttwohours.YYYisthenumberofpaired
poweroptimizersidentifiedduringthemostrecentpairingprocess.IfXXXandYYYare
notequal,theremaybeaprobleminoneormorepoweroptimizers.
l S_OK:TheconnectiontotheSolarEdgemonitoringportalissuccessful(appearsonlyif
theinverterisconnectedtotheserver).
l ON/OFF:IndicatesthepositionoftheinverterON/OFFswitch.
Main Inverter Status
V a c [ V ] V d c [ V ] P a c [ W ]
2 4 0 . 7 3 7 1 . 9 3 2 1 0 . 0
F a c [ H z ] O P s _ O k
T e m p 5 0 . 0 1 1 2 8 . 2
l Vac [V:TheACoutputvoltage.
l Vdc [V]:TheDCinputvoltage.
l Pac [W]:TheACoutputpower.
l Fac [Hz]:TheACoutputfrequency.
l OPs_Ok:Numberofoptimizerssendingtelemetries(indicatingthattheyarepaired)
l Temp [C or F]:Theinverterheatsinktemperature
SolarEdge-Installation Guide MAN-01-00002-4.0
64
Status Screens - Operational Mode