P400 Installation
Table Of Contents
- SolarEdge Installation Guide - North America Version 4.0
- Disclaimers
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimizers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Commissioning the Installation
- Chapter 6: User Interface
- Chapter 7: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Technical Specifications
- Appendix C: Mechanical Specifications
- Appendix D: External Fan Maintenance and Replacement
- Appendix E: Replacing and Adding System Components
- Appendix F: Inverter Arc Detection and Interruption
3. Waitforthecompletionofthepairing(remainingsecondsis0).Ifpairingfails,anerroris
displayed.Inthiscase,repeatthepairingsteps,andrefertoPower Optimizer
Troubleshooting onpage94.Iftheproblempersists,contactSolarEdgeSupport.When
pairingsucceeds,thefollowingmessageisdisplayed:
P a i r i n g
P a i r i n g C o m p l e t e d
4. Thesystemstartupprocessbegins:
5. SincetheinverterisON,thepoweroptimizersstartproducingpowerandtheinverter
startsconvertingAC.
NOTE
When you turn ON the inverter ON/OFF switch, the DC cables carry a high voltage and
the power optimizers no longer output a safe 1V output.
Après avoir mis l'interrupteur ON/OFF de l'onduleur monophasé sur ON, les câbles DC
portent une haute tension et les optimiseurs de puissance ne génèrent plus la tension de
sécurité de 1V.
6. WhentheinverterstartsconvertingpoweraftertheinitialconnectiontotheAC,the
inverterentersStandbymodeuntilitsworkingvoltageisreached.Thismodeisindicated
bytheflickeringgreeninverterLED.
7. WhiletheinverterisinStandbymode,itmonitorsthegridandverifiescorrectgrid
voltageandfrequency.Thefollowingmessageisdisplayed:
W a k i n g U p . . .
R e m a i n i n g : 0 5 1 S e c
ThecountdownindicatesthesecondsremaininguntilenteringtheProduction
mode.Thistimeisinaccordancewithlocalregulationsandistypicallybetween
threetofiveminutes.
Whencountdowniscomplete,theinverterentersProductionmodeandproducespower.
ThesteadilylitgreeninverterLEDindicatesthismode.
8. Forsingle phase inverters only-scrolltotheMaintenancemenuandselectOptimizer
Conf.èSet Rapid ShutdownèEnable.
S e t R a p i d S h u t d o w n
E x i t
SolarEdge-Installation Guide MAN-01-00002-4.0
46
Step 2: Pairing Power Optimizers to the Inverter