P400 Installation
Table Of Contents
- SolarEdge Installation Guide - North America Version 4.0
- Disclaimers
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimizers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Commissioning the Installation
- Chapter 6: User Interface
- Chapter 7: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Technical Specifications
- Appendix C: Mechanical Specifications
- Appendix D: External Fan Maintenance and Replacement
- Appendix E: Replacing and Adding System Components
- Appendix F: Inverter Arc Detection and Interruption
8. Closetheinvertercoverbytighteningthescrewswithatorqueof9.0N*m/6.6lb*ft.For
propersealing,firsttightenthecornerscrewsandthenthetwocentralscrews.The
followingfigureillustratesrecommendedorder:
Figure 30: Tightening order of the screws
9. TurnONtheSafetySwitch.IfanadditionalexternalDCswitchisinstalledbetweenthe
poweroptimizersandtheinverter(s)thenturnitON.
AstatusscreensimilartothefollowingappearsontheLCDpanel:
V a c [ V ] V d c [ V ] P a c [ w ]
2 4 0 . 7 1 4 . 1 0 . 0
P _ O K : 0 0 0 / 0 0 0 < S _ O K >
- - - - - - - - - - - - - - - O F F
10. VerifythatthefollowinginformationappearsontheLCDpanel:
l P_OK:Appearsonlyuponfirsttelemetryreceptionfromthepoweroptimizers.
Indicatesconnectiontothepoweroptimizersandthatatleastonepoweroptimizer
issendingmonitoringdata.IfP_OKdoesnotappear,checkthepoweroptimizer,
stringandDCinputconnections.
l 000/000:Appearsonlyuponfirsttelemetryreceptionfromthepoweroptimizers.
Indicatesthenumberofpoweroptimizersthathavebeenpairedtothisinverter.At
thisstage,thenumbershouldbe000,sincenopoweroptimizershavebeenpaired.
l S_OK:theconnectiontotheSolarEdgemonitoringportalissuccessful(should
appearonlyiftheinverterisconnectedtotheserver).IfS_OKisnotdisplayedand
theinverterisconnectedtotheserver,refertoErrors and Troubleshootingonpage
83.
l Vac [V]:thegridACoutputvoltage.Verifythecorrectvalue.
SolarEdge-Installation Guide MAN-01-00002-4.0
44
Step 1: Activating the System