P400 Installation
Table Of Contents
- SolarEdge Installation Guide - North America Version 4.0
- Disclaimers
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimizers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Commissioning the Installation
- Chapter 6: User Interface
- Chapter 7: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Technical Specifications
- Appendix C: Mechanical Specifications
- Appendix D: External Fan Maintenance and Replacement
- Appendix E: Replacing and Adding System Components
- Appendix F: Inverter Arc Detection and Interruption
l For single phase 10-11.4kW inverters-ConnecttheDCwiresfromthePVinstallationto
theDC+andDC-terminalblocks,accordingtothelabelsontheterminals:
o
Useastandardflat-bladescrewdrivertoconnectthewirestothespring-clamp
terminals.Thescrewdriverbladeshouldfitfreelyintheterminalopening.Too
largeabladecancracktheplastichousing.
o
Insertthescrewdriverandfirmlytiltittopressthereleasemechanismand
opentheclamp.
o
Insertthewireintothetopopening(seeFigure 29).
o
Removethescrewdriver–thewireisautomaticallyclamped.
Figure 29: DC Spring-clamp terminal examples - single phase 10-11.4 kW inverter
l For three phase inverters–Dooneofthefollowing:
o
Safetyswitchversionwithout terminal blocks on the DC side-ConnecttheDC
wiresfromthePVinstallationtotheDC+andDC-terminalsoftheswitch,
accordingtothelabelsintheSafetySwitch.
o
Safetyswitchversionwith terminal blocks on the DC side-ConnecttheDC
wiresfromthePVinstallationtotheDC+andDC-terminalblocks(seealso
Figure 29).
5. IftheSafetySwitchhasapre-assembledRGM,fliptheRGMplateupwardstoitsoriginal
position.
6. ClosetheSafetySwitchcover:Attachtheswitchcoverandsecureitbytighteningthefour
screwswithatorqueof1.2N*m/0.9ft.*lb.
SolarEdge-Installation Guide MAN-01-00002-4.0
42
Connecting the Strings to the Safety Switch