P400 Installation
Table Of Contents
- SolarEdge Installation Guide - North America Version 4.0
- Disclaimers
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimizers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Commissioning the Installation
- Chapter 6: User Interface
- Chapter 7: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Technical Specifications
- Appendix C: Mechanical Specifications
- Appendix D: External Fan Maintenance and Replacement
- Appendix E: Replacing and Adding System Components
- Appendix F: Inverter Arc Detection and Interruption
Appendix F: Inverter Arc Detection and
Interruption
Thearcdetectionoptionmaybedisabledbydefault.ItmustbeenabledwhenUL1699B
complianceisrequired.Whenenabled,theinverterperformsanautomaticself-testforarc
faulteachtimetheinverterwakes-uporisswitchedON.
To enable/disable arc detection:
1. UsetheLCDlightbuttontoenterSetupmode(refertoConfiguring the Inverter Using the
LCD Light Buttononpage55).
2. Short-presstheLCDlightbuttontoreachtheMaintenance menu.
3. SelectAFCI èEnable orDisable.
To manually test the arc detection functionality:
1. MakesuretheinverterON/OFFswitchisturnedON.
2. UsetheLCDlightbuttontoselectMaintenance èManual AFCI Test.
l Ifthetestissuccessful,thefollowingmessageisdisplayed:
M a n u a l T e s t P A S S
Theinverterproductionistheninterrupted(asifarealarcdetectionhasoccurred),
andthefollowingerrormessageisdisplayed(numberedeither150or151):
E r r o r 1 5 1
A r c F a u l t D e t e c t e d
Performmanualrestarttoresumesystemoperation:TurntheinverterON/OFFswitch
toOFFandthentoON.Theinverterperformsanarcdetectionself-testandstarts
normaloperation.
l Ifthetestfails,contactSolarEdgesupport.
To troubleshoot arc-fault failures:
Theinvertercontinuouslyperformsarcdetectionwhileproducingpower.Ifanelectricarc
occurredinthePVsystem,theinverterdetectsitandstopsproducingpower.Thefollowing
errormessageisdisplayed(numberedeither150or151):
E r r o r 1 5 1
A r c F a u l t D e t e c t e d
Appendix F: Inverter Arc Detection and Interruption
SolarEdge-Installation Guide MAN-01-00002-4.0
123