P400 Installation
Table Of Contents
- SolarEdge Installation Guide - North America Version 4.0
- Disclaimers
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimizers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Commissioning the Installation
- Chapter 6: User Interface
- Chapter 7: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Technical Specifications
- Appendix C: Mechanical Specifications
- Appendix D: External Fan Maintenance and Replacement
- Appendix E: Replacing and Adding System Components
- Appendix F: Inverter Arc Detection and Interruption
Three Phase Inverter
Wire color/label Connect to terminal
Figure 60: Three phase inverter AC
terminals
Black / L1 L1
Black / L2 L2
Black / L3
L3 (feeds the internal power
supply)
Green/yellow Ground
White N
3. Tightenthescrewsofeachterminalwithatorqueof1.2-1.5N*m/0.88-1.1lb.*ft.
4. VerifythattherearenounconnectedwiresattheoutputoftheSafetySwitchandthatthe
unusedterminalscrewsaretightened.
Adding, Removing, or Replacing Power Optimizers
1. TurnOFFtheinverterON/OFFswitch,andwaituntiltheLCDindicatesthattheDCvoltage
issafe(<50V),orwaitfiveminutesbeforecontinuingtothenextstep.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait
five minutes for the input capacitors of the inverter to discharge.
Si vous ne pouvez pas voir l'écran de l'onduleur ou si un dysfonctionnement est indiqué sur
l'écran LCD, attendez cinq minutes pour que les condensateurs d'entrée de l'onduleur
soient déchargés.
2. TurnOFFtheSafetySwitchandtheACswitchofthemaindistributionpanel.
3. Disconnectandconnectthenecessarypoweroptimizers.
4. PerformpairingandotherproceduresdescribedinCommissioning the Installationonpage
43onallinverterstowhichpoweroptimizerswereaddedorfromwhichpower
optimizerswereremoved.
5. Inthemonitoringportal,replacetheserialnumberoftheremovedpoweroptimizerwith
serialnumberofthenewlyinstalledpoweroptimizer.
SolarEdge-Installation Guide MAN-01-00002-4.0
122
Adding, Removing, or Replacing Power Optimizers