P400 Installation
Table Of Contents
- SolarEdge Installation Guide - North America Version 4.0
- Disclaimers
- Support and Contact Information
- Contents
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimizers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Commissioning the Installation
- Chapter 6: User Interface
- Chapter 7: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Technical Specifications
- Appendix C: Mechanical Specifications
- Appendix D: External Fan Maintenance and Replacement
- Appendix E: Replacing and Adding System Components
- Appendix F: Inverter Arc Detection and Interruption
SE10000A-US SE11400A-US Units
Rapid Shutdown – NEC 2014 690.12
Functionality enabled when SolarEdge rapid shutdown kit is
installed
1
STANDARD COMPLIANCE
Safety UL1741, UL1699B, UL1998, CSA 22.2
Grid connection standards IEEE1547
Emissions FCC part15 class B
ROHS Yes
INSTALLATION SPECIFICATIONS
AC output conduit size / AWG range 3/4” minimum / 8-3 AWG
DC input conduit size / # of strings / AWG range 3/4” minimum / 1-2 strings / 14-6 AWG
Dimensions (HxWxD) 21 x 12.5 x 10.5 / 540 x 315 x 260 in/mm
Dimensions with Safety Switch (HxWxD) 30.5 x 12.5 x 10.5 / 775 x 315 x 260 in/mm
Weight 82 / 37 lb/kg
Weight with Safety Switch 88.4 / 40.1 lb/kg
Cooling Fans (user replaceable)
Noise (typical) < 50 dBA
Minimum and maximum operating temperature range -13 to +140 / -25 to +60 (-40 to +60 version available
2
) ˚F/˚C
Storage temperature range -13 to +140 / -25 to +60 ˚F/˚C
Protection rating NEMA 3R
1
Rapid shutdown kit P/N: SE1000-RSD-S1
2
-40 version P/N: SExxxxA-US000NNU4
Appendix B: Technical Specifications
SolarEdge-Installation Guide MAN-01-00002-4.0
103