P730-P850 Power Optimizer - North America
Table Of Contents
Power Optimizer For North America
P801 / P850 / P950 / P1100
Power Optimizer Model
(Typical Module
Compatibility)
P801
(for up to 2 x 72-cell
PV modules)
P850
(for up to 2 x high
power or
bi-facial modules)
P950
(for up to 2 x high
power or
bi-facial modules)
P1100
(for up to 2 x
high power or
bi-facial modules)
INPUT
Rated Input DC Power
(1)
800 850 950 1100 W
Connection Method
Single input for series connected modules
Absolute Maximum Input Voltage
(Voc at lowest temperature)
125
Vdc
MPPT Operating Range
12.5 - 105
Vdc
Maximum Short Circuit Current per input (Isc)
11.75 14.1* 14.1
Adc
Maximum Efficiency
99.5
%
Weighted Efficiency 98.6 %
Overvoltage Category II
OUTPUT DURING OPERATION
(
POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current
15 18
Adc
Maximum Output Voltage 80 Vdc
OUTPUT DURING STANDBY (
POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF
)
Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc
STANDARD COMPLIANCE
Photovoltaic Rapid Shutdown System NEC 2014
EMC FCC Part 15 Class A, IEC61000-6-2, IEC61000-6-3
Safety
IEC62109-1 (class II safety), UL1741
Material UL94 V-0, UV Resistant
RoHS Yes
INSTALLATION SPECIFICATIONS
Compatible SolarEdge Inverters
SE9K & larger SE20K & larger SE30K & larger
Maximum Allowed System Voltage 1000 Vdc
Dimensions (W x L x H) 129 x 153 x 49.5 / 5.1 x 6 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in
Weight
933 / 2.05 1064 / 2.34
gr / lb
Input Connector
MC4
(2)
Input Wire Length
0.16 / 0.52 1.3 / 4.27 0.16 / 0.52 1.6 / 5.24 1.3 / 4.27 1.6 / 5.24
m / ft
Output Wire Length
2.2 / 7.2 2.1 / 6.9 2.2 / 7.2 2.2 / 7.2 2.4 / 7.8
m / ft
Output Wire Type / Connector Double Insulated / MC4
Operating Temperature Range
(3)
-40 to +85 / -40 to +185 ˚C / ˚F
Protection Rating
IP68 / NEMA6P
Relative Humidity
0 - 100 %
(1) Rated power of the module at STC will not exceed the Power Optimizer
“Rated Input DC Power”. Modules with up to +5% power tolerance are allowed
(2) For other connector types please refer to: https://www.solaredge.com/sites/default/files/optimizer-input-connector-compatibility.pdf
(3) For ambient temperature above +70˚C / +158˚F power de-rating is applied. Refer to https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf for more
details
PV System Design Using a
SolarEdge Inverter
(4)(5)(6)
208V Grid
SE14.4K*
208V Grid
SE17.3K*
277/480V Grid
SE20K, SE30K,
SE33.3K*, SE40K*
277/480V Grid
SE20K, SE30K
277/480V Grid
SE33.3K*, SE40K*
Compatible Power Optimizers
P801
P850, P950,
P1100
P801
P850, P950,
P1100
P801 P850, P950, P1100 P850, P950, P1100
Minimum String
Length
Power Optimizers
8 8 9 9 14 14 14
PV Modules
15 15 17 17 27 27 27
Maximum String
Length
Power Optimizers
30 30 30 30 30
30 30
PV Modules
60 60 60 60 60
60 60
Maximum Continuous Power per String
6000 7200 7275 8730 12750 15300 15300
W
Maximum
Allowed
Connected
Power
per
String
(7)
(Permitted only when the difference in connected power
between strings is up to 2,000W for the 277/480V grid, or
1,000W for the 208V grid)
2 strings or less
- 7200
1 string - 8400
1 string - 9930
15000
1 string 17550
2 strings or less
- 17550
W
3 strings or
more - 7800
2 strings or
more - 9000
3 strings or
more - 9075
2 strings or
more - 10530
2 strings or
more - 20300
3 strings or
more - 20300
Parallel Strings of Different Lengths or Orientations
Yes
* The same rules apply for Synergy units of equivalent power ratings, that are part of the modular Synergy Technology inverter
(4) P850/P950/P1100 can be mixed in one string only with P850/P950/P1100. P801 cannot be mixed with any other Power Optimizer in the same string
(5) For each string, a Power Optimizer may be connected to a single PV module if 1) each Power Optimizer is connected to a single PV module or 2) it is the only Power Optimizer connected to a single PV module in the string
(6) Design with three phase 208V inverters is limited. Use the SolarEdge Designer for verification
(7) To connect more STC power per string, design your project using SolarEdge Designer
© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SO LAREDGE are trademarks or registered trademarks of SolarEdge Technol ogies, Ltd.
Allothertrademarksmentioned herein aretrademarks of their respectiveowners. Date: 07/2021 DS-00009-4.1-NA. Subject to change without notice.
* For P850/P950 models manufactured in work week 06/2020 or earlier, the maximum Isc per input is 12.5A. The manufacture code is indicated in the Power Optimizer's serial number
example: S/N SJ0620A-xxxxxxxx (work week 06 in 2020)
2 strings or less
- 8475