P700

P730

INPUT
RatedInputDCPower
(1)
700 730 W
AbsoluteMaximumInputVoltage
(Vocatlowesttemperature)
125 Vdc
MPPTOperangRange 12.5-105 Vdc
MaximumShortCircuitCurrent(Isc) 10.1 11 Adc
MaximumDCInputCurrent 12.63 13.75 Adc
MaximumEciency 99.5 %
WeightedEciency 98.6 %
OvervoltageCategory II

MaximumOutputCurrent 15 Adc
MaximumOutputVoltage 85 Vdc

SafetyOutputVoltageperPowerOpmizer 1±0.1 Vdc

EMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3
Safety IEC62109-1(classIIsafety),UL1741
RoHS Yes

CompableSolarEdgeInverters Threephaseinverters
MaximumAllowedSystemVoltage 1000 Vdc
Dimensions(WxLxH) 139x165x63\5.5x6.5x2.5 mm/in
Weight(includingcables) 1185/2.6 gr/lb
InputConnector MC4Compable
OutputWireType/Connector DoubleInsulated;MC4Compable
OutputWireLength 2.1/6.9 m/
OperangTemperatureRange
(2)
-40-+85/-40-+185 ˚C/˚F
ProteconRang IP68/NEMA6P
RelaveHumidity 0-100 %
SolarEdge Power Optimizer Module Add-On
For Commercial Installations for North America P700 / P730



 
MinimumStringLength
(PowerOpmizers)
8 13
MaximumStringLength
(PowerOpmizers)
30 30
MaximumPowerperString 6000
(6)
12750
(7)
W
ParallelStringsofDierentLengths
orOrientaons
Yes
Supportedframe
cross-section
1.1-2.4mm/0.04-0.094in
>12mm/0.48in
(1)
RatedcombinedSTCpowerof2modulesconnectedinseries.Moduleofupto+5%powertoleranceallowed.
2)
Forambienttemperatureabove+70˚C/+158˚Fpowerde-ratingisapplied.RefertoPowerOptimizersTemperatureDe-RatingApplicationNoteformoredetails.
(3)
P600,P700andP730canbemixedinonestring.ItisnotallowedtomixP600/P700/P730withP300/P320/P400/P405inonestring.
(4)
InacaseofoddnumberofPVModulesinonestringitisallowedtoinstalloneP700/P730poweroptimizerconnectedtoonePVModule.
(5)
P700andP730designwiththreephase208Vinvertersislimited.UsetheSolarEdgeSiteDesignerforverification.
(6)
ForSE14.4KUS-208:Itisallowedtoinstallupto6,500Wperstringwhen3stringsareconnectedtotheinverterandwhenthemaximumpowerdifferencebetweenthestringsisupto1,000W.
(7)
ForSE33.3KUS:Itisallowedtoinstallupto15,000Wperstringwhen3stringsareconnectedtotheinverterandwhenthemaximumpowerdifferencebetweenthestringsisupto2,000W.