P400 Zep Compatible Module Add-On - North America
© SolarEdge Technologies Ltd. Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or regiered trademarks of SolarEdge Technologies,
Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2019/V01/ENG NAM. Subject to change without notice.
Power Optimizer - Zep Compatible
TM
Module Add-On For North America
P320-ZEP, P400-ZEP
Optimizer model
(typical module compatibility)
P320-ZEP (for 60-cell modules)
P400-ZEP (for 72 & 96-cell
modules)
INPUT
Rated Input DC power
(1)
320 400 W
Absolute Maximum Input Voltage (Voc at lowe temperature) 48 80 Vdc
MPPT Operating Range 8 - 48 8 - 80 Vdc
Maximum Short Circuit Current (Isc) 11 10.1 Adc
Maximum DC Input Current 13.75 12.63 Adc
Maximum Eciency 99.5 %
Weighted Eciency 98.8 %
Overvoltage Category II
OUTPUT DURING OPERATION
(
POWER OPTIMIZER CONNECTED TO OPERATING INVERTER
)
Maximum Output Current 15 Adc
Maximum Output Voltage 60 Vdc
OUTPUT DURING STANDBY
(
POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF
)
Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc
STANDARD COMPLIANCE
EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety), UL1741
RoHS Ye s
INSTALLATION SPECIFICATIONS
Maximum Allowed Syem Voltage 1000 Vdc
Input Connector MC4
(2)
Output Connector Double Insulated; MC4
Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft
Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F
Protection Rating IP68 / NEMA 6P
Relative Humidity 0 - 100 %
* These specications apply to power optimizers with part number Pxxx-5NM4MTx
(1)
Rated STC power of the module. Module of up to +5% power tolerance allowed.
(2)
Other input connector types available upon reque; contact SolarEdge for details.
PV Syem Design Using a Solaredge Inverter
(3)
Single Phase
HD-Wave
Single phase
Three phase
208v
Three phase
480v
Minimum String Length (Power Optimizers) 8 10 18
Maximum String Length (Power Optimizers) 25 25 50
(4)
Maximum Power per String
5700 (6000 with
SE7600H-US)
5250 6000 12750 W
Parallel Strings of Dierent Lengths or Orientations Ye s
(3)
For detailed ring sizing information refer to: http://www.solaredge.com/sites/default/les/ring_sizing_na.pdf.
(4)
A ring with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement