SE14.4K SetApp Enabled, 3phase 208V, with AC RSD, DC Safety Switch and, DC Fuses and AFCI Specifications
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All 
other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2018/V01/ENG NAM. Subject to change without notice.
Three Phase Inverters 
For the 208V Grid for North America
SE9KUS / SE14.4KUS
SE9KUS SE14.4KUS
APPLICABLE TO INVERTERS WITH PART NUMBER SEXXK-XXXXXNXXX
OUTPUT 
Rated AC Power Output  9000 14400 VA
Maximum AC Power Output  9000 14400 VA
AC Output Line Connections 4-wire WYE (L1-L2-L3-N) plus PE or 3 wire Delta
AC Output Voltage Minimum-Nominal-Maximum
(2)
 (L-N) 105-120-132.5 Vac
AC Output Voltage Minimum-Nominal-Maximum
(2)
 (L-L) 183-208-229 Vac
AC Frequency Min-Nom-Max
(2)
59.3 - 60 - 60.5 Hz
Max. Continuous Output Current (per Phase)  25 40 A
GFDI Threshold  1 A
U t i l i t y  M o n i t o r i n g ,  I s l a n d i n g  P r o t e c t i o n ,  C o u n t r y  C o n  g u r a b l e  S e t  P o i n t s                                                                              Ye s  
INPUT 
Maximum DC Power (Module STC) 12150 19400 W
Transformer-less, Ungrounded  Ye s  
Maximum Input Voltage DC to Gnd  250 300 Vdc
Maximum Input Voltage DC+ to DC- 500 600 Vdc
Nominal Input Voltage DC to Gnd 200 Vdc
Nominal Input Voltage DC+ to DC- 400 Vdc
Maximum Input Current  26.5 38 Adc
Maximum Input Short Circuit Current 45 Adc
Reverse-Polarity Protection Ye s  
Ground-Fault Isolation Detection  1MΩ Sensitivity  350kΩ Sensitivity
(3)
CEC Weighted Eciency  96.5 97 %
Night-time Power Consumption < 3 < 4 W
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, Ethernet, ZigBee (optional)
Rapid Shutdown – NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect
RS485 Surge Protection Supplied with the inverter
STANDARD COMPLIANCE 
Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07  
Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)   
Emissions FCC part15 class B  
INSTALLATION SPECIFICATIONS 
AC output conduit size / AWG range 3/4” minimum / 12-6 AWG 3/4” minimum / 8-4 AWG
DC input conduit size / AWG range 3/4” minimum / 12-6 AWG
Number of DC inputs 2 pairs 3 pairs
(4)
Dimensions (H x W x D) 21 x 12.5 x 10.5 / 540 x 315 x 260 in / mm
Dimensions with Safety Switch (H x W x D) 30.5 x 12.5 x 10.5 / 775 x 315 x 260 in / mm
Weight  73.2 / 33.2 99.5 / 45 lb / kg
Weight with Safety Switch 79.7 / 36.2 106 / 48 lb / kg
Cooling  Fans (user replaceable) 
Noise < 50  < 55  dBA
Operating Temperature Range  -40 to +140 / -40 to +60
(5)
  ˚F / ˚C
Protection Rating  NEMA 3R
(1)
 For 277/480V inverters refer to: https://www.solaredge.com/sites/default/les/se-three-phase-us-inverter-datasheet.pdf
(2)
 For other regional settings please contact SolarEdge support
(3)
 Where permitted by local regulations
(4)
 Field replacement kit for 1 pair of inputs P/N: DCD-3PH-1TBK; Field replacement kit for 3 pairs of fuses and holders P/N: DCD-3PH-6FHK-S1
(5)
 For power de-rating information refer to: https://www.solaredge.com/sites/default/les/se-temperature-derating-note-na.pdf