SE14.4K SetApp Enabled, 3phase 208V, with AC RSD, DC Safety Switch and, DC Fuses and AFCI Installation

2
Optimizer Inverter Allowed Distance
The total cable length of the string from the extended power three phase inverter to the farthest power optimizer is 1,150ft (2,300ft
from DC+ to DC- of the inverter).
DC Input
The extended power and commercial three phase inverters are provided with an integrated DC Safety Switch and with terminal
blocks for the connection of three strings per unit, eliminating the cost of an external DC combiner box. If an external combiner box
is preferred, a field replacement kit for 1 pair of inputs designed to carry the full current may be purchased (part number: DCD-3PH-
1TBK). If DC fuses are needed, a field replacement kit for 3 pairs of fuses and holders may be purchased (part number: DCD-3PH-
6FHK-S1).