After scanning the bar code of battery, there
are some personal messages need to be filled
which noted by “*” symbol.
3
After those messages filled and signature, the APP would jump to the
running interface automatically.
NOTICE
The CFE Residential ESS could be registered only one time.
The CFE Residential ESS running is not associated with registration or
not.
6.3 Settings for CAN /485 bus pins
Confirm that the CANL/485B DIP switch is set to SW4 which pin is used for CAN
high signal by inverter (4-CANH/485A), and the CANL/485B DIP switch is set to
SW5 which pin is used for CAN low signal by inverter (5-CANL/485B).
As SW3 the CAN/485 GND/DIP switch, installer should confirm which pin is used for
ground by inverter or not.
NOTICE
The battery default protocol is CAN bus, if an inverter communication
mode is RS485 or other protocol, please contact CFE customer
careline before installed the battery.