Specifications
5
Inverter to Panel Selection
Inverter
Model
Qty
AC Wiring Configuration Required Panels
Options that
allow future
expansion of
additional
PAE inverters
Continuous
Power
Output at
25° C
SISO =
Single in, Single out – 120 VAC
DIDO =
Dual in, Dual out – 120/240 VAC
MMP: 1 inverter only
MPSL: 1-2 inverter capability
MPSH: 2-3 inverter capability
MPDH: 2-4 inverter capability
MPX: Expansion box, 1 unit
capability
MS2012 1 SISO-60 MMP250-60S See page 1 NA 2.0 KVA
1 DIDO MMP250-30D See page 1 NA 2.0 KVA
MS2812 1 SISO-60 MMP250-60S See page 1 NA 2.8 KVA
1 DIDO MMP250-30D See page 1 NA 2.8 KVA
MS4024 1 SISO-60 MMP250-60S See page 1 NA 4.0 KVA
1 DIDO MMP250-30D See page 1 NA 4.0 KVA
2 SISO-60 (series stacked)
MPSL-60S +
MPX-60S
See page 2 NA 8.0 KVA
2 DIDO
MPSL-30D +
MPX-30D
See page 2 MPSH-30D + MPX-30D 8.0 KVA
MS4024PAE 1 DIDO MMP250-30D See page 1 NA 4.0 KVA
2 DIDO x 2
MPSL-30D +
MPX-30D
See page 2
MPSH-30D + MPX-30D or
MPDH-30D
8.0 KVA
3 DIDO x 3
MPSH-30D +
MPX-30D (x2)
See page 3 MPDH-30D + MPX-30D 12.0 KVA
4 DIDO x 4
MPDH-30D +
MPX-30D (x2)
See page 4 NA 16.0 KVA
MS4448PAE 1 DIDO MMP175-30D See page 1 NA 4.4 KVA
2 DIDO x 2
MPSL-30D +
MPX-30D
See page 2
MPSH-30D + MPX-30D or
MPDH-30D
8.8 KVA
3 DIDO x 3
MPSH-30D +
MPX-30D (x2)
See page 3 MPDH-30D + MPX-30D 13.2 KVA
4 DIDO x 4
MPDH-30D +
MPX-30D (x2)
See page 4 NA 17.6 KVA
Magnum Panel Selection Guide
Reading Magnum Panel Part Numbers
Available
Magnum Panel
part numbers:
MPSL-30D
MPSL-60S
MPSH-30D
MPDH-30D
Magnum Panel part numbers follow the same three-part pattern: MPSL-30D,
which may be broken down into:
MP SL - 30D
30D
30 AAC Double-pole, input circuit breaker(s).
x1 for single box or x2 for dual box
60S 60 AAC Single-pole, input circuit breaker
SL
Single box, low capacity – includes 60 AAC bypass, 500 ADC
shunt and one 250 ADC breaker. Capability for 1-2 inverters
SH
Single box, high capacity – includes 125 AAC bypass, 1000 ADC
shunt and one 250 ADC breaker. Capability for 2-3 inverters
DH
Dual box, high capacity – includes 125 AAC bypass, 1000 ADC
shunt and two 250 ADC breakers. Capability for 2-4 inverters
MP Magnum Panel