Specifications
2
MPSL - Magnum Panel
The MPSL shown with a single inverter
(sold separately).
The MPSL shown with two inverters (sold separately),
an MPX extension to accommodate a second inverter,
an optional dual backplate, and an optional router.
The MPSL – Magnum Panel, Single Enclosure, Low Capacity – is designed to accommodate a
maximum of two inverters.
FEATURES:
Expandable: start with
the enclosure and just one
inverter and in the future
expand to two inverters
with ease, using the MPX.
Easy installation:
all connections are front-
mounted, including AC and
DC breakers and the MPX.
Labor saving: panel is pre-
wired for fast installation,
saving labor costs.
DC load breakers:
fits
either din rail or back-
mount DC load breakers.
Convenient knockouts:
knockouts on the side
of the enclosure are
compatible with most
charge controllers.
INCLUDES:
One DC breaker – 250A
One 60A AC bypass breaker
500A/50mv DC shunt
Inverter AC input protection
MPX extension includes
AC/DC circuit protection
and wiring
PART NUMBERS
MPSL-30D
MPSL-60S