User guide

15 rev.1011 MKTG-IM-TP-12-002
Installation and Owner’s Manual | TP Series Solar LED Lighting System
FIGURE 18 aiSUN™ CONTROLLER (ETERNO® 4 OPERATES SIMILARLY)
Test Button
Diagnostic Indicators
2.11 Testing the System
After the battery is installed and the components are connected, press the test button
(Figure 18). The LED fixture should illuminate at full intensity for five minutes, and the LED
diagnostic indicator should be ON (illuminated).
One or more additional diagnostic indicators may also be ON. The indicators
will remain ON for approximately five seconds after pressing the test button.
The diagnostic indicators on the controller indicate the status of the TP Series lighting
system:
* If the battery voltage is too low, contact Sol Customer Service at +1-772-286-9461.
After the TP lighting system is tested and found to be satisfactory, secure the battery box
cover to the battery box by closing it or replacing cover, using the 1/4”-20 x 1/2” hex
head bolts.
Indicator Status Description
LED ON The LED fixture is illuminated.
OFF The LED fixture is off.
DIM ON The LED fixture is in the Power Save mode. Contact Sol.*
OFF Dimming is not active due to Power Save. Battery voltage is OK.
Charge ON The controller is charging the battery.
OFF The controller is not charging the battery.
Low Volt Disconn Flashing The battery is either disconnected or too low. Contact Sol.*
OFF Battery condition is OK.
Code 2 Reserved for future use.
Code 1 ON If system is a dual LED fixture system, one fixture is disconnected.
OFF Fixtures are OK.
Fault ON LED fixture issue: short circuit or open circuit.
OFF Fixtures are OK.