Instructions / Assembly
 E
OS
 13 
O
BSTACLE 
S
ENSING
If the lead rail comes in contact with an obstacle while operating, the E
OS
 will 
stop. When this happens, do the following: 
1.  Clear the obstacle from the lead rail travel path. 
2.  Briskly shake the lead rail to simulate a strong wind. The awning will 
close. Normal operation will resume after the wind extend reattempt 
delay time has expired (see Wind Sensing). 
3.  When using the SOL-LUX Mobile App: 
a.  If the awning was blocked while opening, close the awning using 
the close button. 
b.  If the awning was blocked while closing, open the awning using the 
open button. Normal operation will then resume. 
B
ATTERY 
M
ONITORING
The E
OS
 monitors the battery condition to ensure safe and reliable awning operation. 
Charge
 – If the battery charge level falls below 7%, the awning will not open. 
If the awning is open when this occurs, it will close until the battery is 
sufficiently charged to resume normal operation. 
Temperature
 – If the internal temperature of the battery is too high or too 
low, the awning will close and disable operation. This is a safety setting.  
When the internal temperature returns to within the acceptable temperature 
operating range, normal operation will resume.
S
ERVICE 
M
ODE
If it becomes necessary to service your E
OS
, the awning may be placed in Service 
Mode. Autonomous functions will be disabled while in this state. 
1.  Manually close the awning if open (see page 15). 
2.  Remove the awning from the mounting plate (see page 15). 
3. 
Disconnect the battery (it is not necessary to remove the battery).
F
ACTORY 
P
RESET 
V
ALUES FOR 
A
UTONOMOUS 
F
UNCTIONS
Daylight Sensitivity: 
See NOTE 
Extension Delay Time  1 Minute  See NOTE 
Retraction Delay Time  20 Minutes  See NOTE 
1
s
t
 Extend Reattempt Delay Time  60 Minutes  See NOTE 
2
n
d
 Reattempt Delay Time  120 Minutes  See NOTE 
Minimum Operating Awning Temperature  40°F (4.5°C)  See NOTE 
Minimum Charge  7%  Fixed 
Maximum Internal Battery Temperature  140°F (60°C)  Fixed 
Minimum Internal Battery Temperature  5°F (-15°C)  Fixed 
NOTE: Preset values may be adjusted with the SOL-LUX Mobile App. 
OPEN
CLOSE