AUTOMATIC CALIBRATION
When the EOS is properly mounted and stationary for 1 minute, the awning will detect
that the installation is complete and start the calibration.
One short beep indicates that the awning is ready to begin the calibration.
There will be an audible 30 second countdown.
The E
OS will open and close as part of the calibration.
After the calibration, the awning will function based on the factory preset automatic
function settings.
NOTE: After calibration, the Bluetooth connectivity remains in an unlocked state
for 15 minutes so you can pair your devices using the SOL-LUX Mobile App.
After 15 minutes, the Bluetooth connectivity is locked. Refer to the SOL-LUX
Mobile App manual for pairing your devices at a later date.
S
OUND
N
OTIFICATIONS
:
Beep Pattern Meaning
3 short beeps
Battery connected
1 short beep
Awning recognizes calibration request
Calibration complete
Persistent long beeps that
become short, frequent beeps
Awning is starting the calibration.
1 long beep
The awning failed calibration due to wind or
movement.
2 long beeps
Awning failed calibration
Obstruction prevented the awning from fully
extending during calibration.
The awning is not level.
3 long beeps
Battery charge is too low to attempt calibration.
4 long beeps
Battery temperature is out of operating range.
A
UTO
R
ECALIBRATION
To maintain optimal performance over the life of the product, the Eos will perform
an auto recalibration every 100 days of continuous operation.
The recalibration occurs during the next extend operation immediately following a
completed 100 day cycle. The awning will open and close as part of the
calibration then open to the normal extension.
If the awning fails recalibration, the awning will sound the appropriate beep
pattern alert, retract, enter service mode, and reattempt to calibrate once every
24 hours until it either succeeds or the battery becomes critically low.