Discover Operating Manual

10
discoverbattery.com
CAUTION!
Do not charge battery higher than 3.4 V per cell module.
NOTE!
Recommended charge current is 0.5C
Model
Cell Modules
in Series
Bulk Current
Bulk
Voltage
Termination
Charge Current
44-24-2800 8S 110 Adc maximum 27.2 V
I2 ≤ 2 A
42-48-6650 16S 130 Adc maximum 54.4 V
7.4 Discharging
Set the battery to ON
Set the load to ON
Recommended low voltage cut off: 24 V | 48 V
NOTE!
Do not discharge battery below recommended minimum
operating voltages.
NOTE!
Do not discharge battery at rates greater than
recommended operating currents.
7.5 Storage
Systems should be stored out of direct sunlight under the following temperature conditions:
Minimum Storage Temperature -20°C / -4°F
Maximum Storage Temperature 45°C / 113°F
Systems should be put into storage at 80% SOC and checked monthly to ensure SOC does not fall below 20%.
At 20% SOC the battery will self discharge in approximately 2 months.
CAUTION!
Do not store a discharged battery. Recharge battery after
every use. Batteries that have self-discharged to a severely
discharge state are not recoverable.
8. Service & Maintenance
8.1 Warranty Registration
To register your product you will need the serial number of the battery. Visit discoverbattery.com for registration details.
8.2 Inspection
Batteries should be carefully inspected on a regular basis in order to detect and correct potential problems before they do harm. This
routine should be started when the batteries are rst received.
Inspect for cracks in the battery casing
Check battery terminals and connections to make sure they are clean, free of dirt, uids and corrosion
All battery cables and their connections should be tight, intact, and NOT broken or frayed
Replace any damaged batteries
Replace any damaged cables
Ensure correct torque is used for the terminal bolts