Installation & Assembly

Spa Owner’s Manual
- 17 -
How to replace the quartz sleeve: Before replacing or clearing the quartz sleeve (part ), you are obligated to close the two small ball valves on
the inlet and outlet of the chamber. If not, the water will come out from the entry of the chamber.
When your SPA is not in use: If you are going away for a period longer than 2 months, it is recommended that you turn your spa off and empty it. It
is important to remember to leave the cover on even while empty to protect the shell. If you are going away for a few days or weeks, do not turn your spa
off completely. Turn the temperature down to 15 degree, so that the filtration cycles are still functioning but the spa doesn't heat.
3-5 days: Test PH and sanitizer levels of the spa water and adjust it if necessary (please check the water maintenance for details); cover the spa;
test water balance and adjust if necessary before using the spa again.
5-14 days: Setting the lowest temperature or sleep mode. Adjust the PH and water treating (please check the water maintenance for details); cover
the spa cover; adjust the PH and water treating when you reuse the spa.
More than 15 days: Turn off the power; open the drain valve and drain the spa; remove the paper filter; keep the spa dry and put the spa cover and
protection bag on it.
1. Fix the UV chamber vertically
and then insert the quartz sleeve
2. Put the O-ring on
the quartz sleeve
3. Slid down the O-ring to
the outlet of the chamber
4. Tighten the big aluminum
nut to the chamber