◼ UV disinfection system maintenance (option): It is mandatory that the UV lamp (part ④) is replaced and the quartz thimble (part ⑥) is cleaned
every 12 months to maintain optimum performance.
➢ How to replace the UV lamp: Loosen the waterproof strainer (part ①) and then swivel the small aluminum nut (part ⑩) anti-clockwise to take the
UV lamp out. Pull out the old UV lamp (part ④) from the socket (part ③) and then insert the new one to it and then put it to the chamber (part ⑦)
again. Do not loosen the big aluminum nut (part ②) when you replace the UV lamp. If not, the water will come out from the entry of chamber.
WARNING: Germicidal ultraviolet rays are harmful to eyes and skin. Do not open the UV chamber when it is still powered on.