Instructions

itnetworks.soing.com/XG
40
TOOLS
Individual BERT test
Transmission format Standards reference
Required Bit Error Rate in
standards reference
Test time for 10%
confidence level
Test time for 63%
confidence level
Test time for 95%
confidence level
Confidence level with
10 second test time
1G IEEE Std 802.3ab
10
-10
1 second 10 seconds 30 seconds 63,0%
2.5G IEEE Std 802.3bz
10
-12
42 seconds 6 minutes 38 seconds 19 minutes 58 se conds 2,5%
5G IEEE Std 802.3bz
10
-12
21 seconds 3 minutes 19 seconds 9 minutes 59 seconds 4,9%
10G IEEE Std 802.3an
10
-12
11 seconds 1 minute 39 seconds 5 minutes 0 seconds 9,5%