User manual

3-18
Setup
Stress Test - Accuracy
Chapter 3
Accuracy
Select one box for both throughput and back-to-back to measure the
accuracy. The lower the number the faster the test.
Stress test Screen
Throughput
Latency
NOTE: Press the DOWN arrow on the right of the screen to scroll to the
next page of parameters.
SEARCH is the test time for each test while searching for the
maximum error-free throughput.
VALIDATE is the validation test time for the final error-free throughput
validation and all latency tests.
TIME sets the wait time at the end of every test before checking the
results. This allows the data to have propagated to the other end and
also allows for all intermediate devices to recover.
NUMBER selects the number of Latency tests. This is the number of
times the Latency test is repeated.