SG.IN.AN_Operating_instructions
Table Of Contents
SoftGripper and SoftActuators 
Operating Instructions 
info@soft-gripping.com  Revision 2.0 
www.soft-gripping.com
  2022-01-21 
www.soft-gripping.shop  Page 11 
 Warning! Use compressed air according ISO 8573-1:2010 [7:4:4] with maximum pressure 1,2 bar! 
Connect the tubing to the corresponding push-in-fittings H and C. Robot Connectors always have 2 of it. The 
function depends on your selected SoftGripper. 
SoftGripper with up to 4 Fingers have the option of mounting an 
additional suction cup. Accordingly, one of the push-in-fitting is for supplying the fingers, the other for the suction 
cup. If you don´t want to use a suction cup, only the push-in-fitting for the finger supply must  be connected. 
SoftGrippers with more than 4 fingers only have a mounting thread for accessories such as spacers, not for suction 
cups. According to this, both of the push-in-fittings are for supplying the fingers and have to be connected. 
Verify, that all needed connections are made, before operating the setup. Test it with lower pressure. 
Figure 9: Connect the Tubing 