Manual
9 RecordSetup
Clickonthe buttontogototheRecordSetupinterface.
Theeve
ntsarerecordedwhenaspecifiedtriggervalueis encounteredononeoracombination of
axisontheaccel erometer.Thetriggersignaltype,triggervalueandunitsandtheaxistomonitorare
setusingthecontrolsatthetopofth
einterface.
Tworecordtimesaretobeset.Thefirstoneistherecordlengthbeforetriggerandthesecondone
is the record time after trigger. The total record time for one eventwill be the sumof these two
durations.Itisrecommendedtousearecordtimebef
oretriggerofatleast1storecordthetransient
occurringatavibrationevent.Therecordtimeaftereventisusuallylongerandcanrangefrom2 sfor
shorteventsupto20sforlongerevents.
AfterBefore
The SPL (So
und Pressure Level) sampling rate is set from a variety of choice
s. The defaul t rate is
0.05sandisappropriateforalltimeweighting(Slow,FastandImpulse).
Therecordfolderisthedirectoryinwhichthefileswillbestored.Tochangeorcreateanewfolder,
clickonthefieldtodisplayanexplorerdialogallowingthec
hange.
OpusBuildingVibUserGuide–V1.1 21