Datasheet
SONARANGE UPS 09.16 e
This Information corresponds to the current state of knowledge. SNT reserves the right to make technical changes. Do not use these products in any application
where failure of the product could result in personal injury. Liability for consequential damage resulting from the use of SNT products is excluded.
SNT Sensortechnik AG, Hammerstrasse 6, CH-8180 Bülach, Switzerland, Phone +41 44 817 29 22, Fax +41 44 817 10 83, info@sntag.ch 3/5
www.sntag.ch
Place the object to the lower measuring limit
(i.e. where 0V or 4mA is expected)
Teach lower measuring limit with –U
B
Place the object to the upper measuring limit
(i.e. where 10V or 20mA is expected)
Teach upper measuring limit with +U
B
Lower and upper measuring limits can also later be
programmed individually. The teach wire must not be
connected during normal operation. The sensor can e.g. be
operated after teaching with a 3 wire cable.
LED indicator
LED red
LED yellow
During teach-in:
- object detected
- no object detected
- object not reliably detected
off
blinking
on
blinking
off
off
Normal operation PNP
Normal operation analogue
off
off
switching status
on
Error
on
last status
Mounting
The sensor can be mounted with the two M12 nuts (HEX 17)
which are scope of delivery.
Inclination angle of object
Smooth surfaces can be detected up to an inclination angle
of approx. 10°. However rough and structured (granular)
surfaces can be detected up to much higher angles.
Cable
The sensors have an M12 4-pin connector for screw
mounting. The cable should not be mounted parallel or close
to high current cables. Cables have to be ordered separately.
Electrical connections (view to the sensor)
UPS … TVPA 24 C
UPS … TOR 24 CA
UPS … TOR 24 CI
Scope of delivery
Sensor
2 M12 nuts
Accessories (see also data sheet ‚ACC’)
PUR cable 3-wire (pin 1, 3, 4) with M12 connector:
l=2m Type KAB 2L3VGPUR
PUR cable 4-wire with M12 connector:
l=2m Type KAB 2L4VGPUR
PUR cable 4-wire with M12 connector:
l=5m Type KAB 5L4VGPUR
Teach-In box: see separate data sheet
1
2
3
4
1 +24VDC (braun/brown)
2 Teach (weiss/white)
3 0V (blau/blue)
4 OUT P N P (schwarz/black)
1
2
3
4
1 +24VDC (braun/brown)
2 Teach (weiss/white)
3 0V (blau/blue)
4 OU T 0...10V (schwarz/black)
1
2
3
4
1 +24VDC (braun/brown)
2 Teach (w eiss/white)
3 0V (blau/blue)
4 OUT 4...20m A (schw arz/black)